  1. Changes in the 2024 International Building Code (IBC)

    Oct 16, 2009 · The 2024 IBC® contains many important changes such as: Duties and powers of the building official: an overall reformat of Section 104 regulating duties of the building official, the …

  2. Occupancy Classification for Townhouse: R-2 or R-3?

    Oct 17, 2009 · R-2: "Residential occupancies containing more than two dwelling units" If each townhouse is a seperate structure, than it only contains one dwelling unit. That makes it R-3, yes?

  3. New Building One Exit - The Building Code Forum

    Apr 25, 2023 · Yes, Sections 1006.3.3 (2018 IBC) and 1006.3.4 (2021 IBC). Although the sections refer to single exits from a story, each story of a building can use the same single exit.

  4. Egress Capacity Calculator - 2024 IBC

    Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020.3, and Section 1010.1.1 for doors.

  5. Fire rating of electrical equipment rooms - The Building Code Forum

    Dec 17, 2010 · Could anyone direct me to an IBC or NFPA code regarding the rating of electrical equipment rooms. In our jurisdiction, we routinely expect at least a...

  6. Townhouse - The Building Code Forum

    Jul 22, 2015 · Chapter 11 of the IBC and Fair Housing guidelines are applicable SECTION R320 ACCESSIBILITY R320.1 Scope. Where there are four or more dwelling units or sleeping units in a …

  7. 1006.2.1 Egress based on occupant load and common path of egress …

    Dec 23, 2020 · 2021 IBC Section 1006.2.1 requires that two exit or exit access doorways shall be provided to any space if the design occupant load or the common path of egress travel exceeds the …

  8. 1, single user, unisex toilet room in coffee shop, per 2021 IBC

    Feb 24, 2025 · The IBC Commentary language for exception #5 confirms this. There is also the exception under the calculations portion , 2902.1.1, reading "Distribution of the sexes is not required …

  9. S-1 occupancy, occupant load | The Building Code Forum

    Mar 15, 2022 · 2015 IBC, table 1004.1.2, what does a s-1 storage occupancy (repair garage with ordinary hazard) fall under for the occupant load factor? im thinking industrial at 200 sf per person

  10. Fire Separation Distance Between New and Existing Building with …

    Feb 7, 2024 · From the 2021 IBC Commentary: The Commentary says: Fire separation distance is the distance from the exterior wall of the building to one of the three following locations, measured …